Technical Information
Case Dimensions
Military Dimensions
Tolerances
Screw-stud lengths
Tolerances on dimensions
symmetrically locked
Power Transformer
Small Toroid Transformers
non-standard mounting canters
Open Frame Impregnated May 13, 2008
Sealed Encapsulated
Hermetic Metal Cased
Grade Type of Component
Custom Transformers
You've learned this stuff in school and throughout your career. But what is that formula? Where is that old textbook? You're under a deadline - you're near panic!
But then you remember that Mitchell Electronics has a lot of technical information posted on their website. Will what you need be there? Yes! There it is!
You finish your design and submit it in plenty of time - all because you didn't have to dig through old files and textbooks to find the technical information you were looking for
Mitchell Electronics MEC
Standard Mil-T-27 Cases Dimensions (inches)
Prototype Transformers
Case
Symbol
Case Dimensions Military Dimensions
L W H ML MW F
AF 3/4 3/4 1 1/8 13/16 * -- 4/40 x 3/8
AG 1 1 1 3/8 1 1/8 * -- 6 - 32 x 3/8
AH 1 5/16 1 5/16 1 3/4 S:1 1/4 -- 6 - 32 x 3/8
AJ 1 5/8 1 5/8 2 3/8 1 1/16 1 3/16 6 - 32 x 3/8
EA 1 15/16 1 11/16 2 1/4 1 3/8 1 1/4 6 - 32 x 3/8
EB 1 13/16 1 13/16 2 1/16 1 3/8 1 1/4 6 - 32 x 3/8
FA 2 3/16 2 1/16 3 1/8 1 11/16 1 7/16 6 - 32 x 3/8
FB 2 5/16 2 1/16 2 1/2 1 11/16 1 7/16 6 - 32 x 3/8
GA 2 3/4 2 3/8 3 13/16 2 1/8 1 3/4 6 - 32 x 3/8
GB 2 3/4 2 3/8 2 13/16 2 1/8 1 3/4 6 - 32 x 3/8
HA 3 1/16 2 5/8 4 1/4 2 19/64 1 35/64 6 - 32 x 3/8
HB 3 1/16 2 5/8 3 3/16 2 19/64 1 35/64 8 - 32 x 3/8
JA 3 9/16 3 1/16 4 7/8 2 5/8 2 1/8 8 - 32 x 3/8
JB 3 9/16 3 1/16 3 7/8 2 3/8 2 1/8 8 - 32 x 3/8
KA 3 15/16 3 3/8 5 1/4 3 2 1/16 10 - 32 x 1/2
KB 3 15/16 3 3/18 4 5/16 3 2 1/16 10 - 32 x 1/2
LA 4 3/16 3 11/16 5 9/16 3 5/16 2 11/16 10 - 32 x 1/2
LB 4 3/16 3 11/16 4 1/2 3 3/16 2 11/16 10 - 32 x 1/2
MA 4 11/16 4 6 3 11/16 3 1/4 - 20 x 5/8
MB 4 11/16 4 4 15/16 3 11/16 3 1/4 - 20 x 5/8
NA 5 1/16 4 5/16 6 13/16 4 1/16 3 1/16 1/4 - 20 x 5/8
NB 5 1/16 4 5/16 5 1/2 4 1/16 3 5/16 1/4 - 20 x 5/8
OA 5 1/2 4 1/2 6 3/4 3 3/4 3 1/4 - 20 x 5/8
* Not in conformance with MIL-T-27 S: Two studs in a diagonal.
YY All metal cases not included above or with non-standard mounting canters.
ZZ Open type and encapsulated units.
1. Tolerances on dimensions L and W are +0 to -1/16 for cases AF, AG, AH and AJ; +0 to -1/8 for all other cases.
2. Tolerances on dimension H are +0 to - 1/8 for cases AF, AG, AH, and AJ; +0 to -3/16 for all other cases.
3. Tolerances on dimensions ML and MW are ±1/16 for cases AJ to JB inclusive: ±1/32 for cases KA to LB, inclusive; and ±3/64 for cases MA to CA, inclusive. When mounting studs or holes for inserts are used, they shall be symmetrically locked.
4. Screw-stud lengths are from mounting surface and have a length tolerance of ±1/16 on studs 1/2" long or less and ±1/8 on studs over 1/2" long.
Back to Technical Information home page

We're happy to have you as a visitor to our website.

Enjoy your stay, and please contact us for your transformer needs.

We'll treat you like family!
Secondary AC Current Requirements
Phone: 914-699-3800
Fax: 914-699-1022
Address: 85 West Grand Street
Mt. Vernon, NY 10552
Email: info@yesmec.com
Hermetically Sealed Audio
 
RF Circuits